				| Item | Description | 
|---|---|
| Memory (RAM) | 1 GB | 
| Flash | 512 MB in total. To view the available flash memory size, run the display version command. | 
| Mean time between failures (MTBF) | 92.2 years | 
| Mean time to repair (MTTR) | 2 hours | 
| Availability | > 0.99999 | 
| Service port surge protection | Common mode: ±7 kV | 
| Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode | 
| Dimensions (H x W x D) | 
 | 
| Weight (with packaging) | 4.31 kg (9. lb) | 
| Stack ports | Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) | 
| RTC | Not supported | 
| RPS | Not supported | 
| PoE | Supported | 
| Rated voltage range | 
 | 
| Maximum voltage range | 
 | 
| Maximum power consumption (100% throughput, full speed of fans) | 
 | 
| Typical power consumption (30% of traffic load)
 
 | 39 W | 
| Operating temperature | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
 NOTE:
 When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). | 
| Short-term operating temperature | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
 When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
 
 The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. | 
| Storage temperature | -40°C to +70°C (-40°F to +158°F) | 
| Noise under normal temperature (27°C, sound power) | < 57.7 dB(A) | 
| Relative humidity | 5% to 95%, noncondensing | 
| Operating altitude | 0-5000 m (0-16404 ft.) | 
| Certification | 
 | 